Surgery unit alert system Gas Pressure Alarm Series
for MGPSfor healthcare facilitiesfor medical gas pipeline systems

Surgery unit alert system - Gas Pressure Alarm Series - Jiangsu Fuyou Medical - for MGPS / for healthcare facilities / for medical gas pipeline systems
Surgery unit alert system - Gas Pressure Alarm Series - Jiangsu Fuyou Medical - for MGPS / for healthcare facilities / for medical gas pipeline systems
Surgery unit alert system - Gas Pressure Alarm Series - Jiangsu Fuyou Medical - for MGPS / for healthcare facilities / for medical gas pipeline systems - image - 2
Surgery unit alert system - Gas Pressure Alarm Series - Jiangsu Fuyou Medical - for MGPS / for healthcare facilities / for medical gas pipeline systems - image - 3
Surgery unit alert system - Gas Pressure Alarm Series - Jiangsu Fuyou Medical - for MGPS / for healthcare facilities / for medical gas pipeline systems - image - 4
Surgery unit alert system - Gas Pressure Alarm Series - Jiangsu Fuyou Medical - for MGPS / for healthcare facilities / for medical gas pipeline systems - image - 5
Surgery unit alert system - Gas Pressure Alarm Series - Jiangsu Fuyou Medical - for MGPS / for healthcare facilities / for medical gas pipeline systems - image - 6
Add to favorites
Compare this product

Characteristics

Applications
for surgery units, for MGPS, for healthcare facilities, for medical gas pipeline systems, for medical gas
Type
wall

Description

Product description
The regional gas pressure alarm panel is designed for monitoring medical gas supply pipeline pressure in areas such as ward floors, nurse stations, operating rooms, ICU gas manifolds and gas valve boxes. It displays the monitored gas pressure in real time on a 0.8-inch digital tube. The pressure sensor connects to the gas pipeline and outputs a digital carrier signal to the host, allowing electronic detection of pressure variations.

Details
Surface-mounted unit with high-precision electric contact pressure gauge (class 1.6)
Number of pressure monitoring points: 1–6 channels
Detection range: 0.1MPa~1MPa (adjustable)
Alarm method: sound and light warning
Buzzer mute: default auto-recover after 10 minutes; alarm restores upon detection of a new abnormality
Host power supply voltage: DC24V ± 6%
Can be customized for multiple medical gases

Technical specifications
  • Surface-mounted unit with high-precision electric contact pressure gauge (class 1.6)
  • Number of pressure monitoring points: 1–6 channels
  • Detection range: 0.1MPa~1MPa (adjustable)
  • Alarm method: sound and light warning
  • Buzzer mute: default silent recovery time 10 minutes; alarm restores upon new abnormality detection
  • Host power supply voltage: DC24V ± 6%
  • Can be customized for multiple medical gases