Thermostatic test chamber BIER-S100
temperaturepressurelaboratory

Thermostatic test chamber - BIER-S100 - Tailin - temperature / pressure / laboratory
Thermostatic test chamber - BIER-S100 - Tailin - temperature / pressure / laboratory
Add to favorites
Compare this product

Characteristics

Type
thermostatic
Controlled parameter
temperature, pressure
Applications
laboratory, for the pharmaceutical industry, medical
Configuration
floor-standing
Other characteristics
automatic, high-performance, steam
Capacity

5 l
(1.3 gal)

Temperature range

Min.: 110 °C
(230 °F)

Max.: 145 °C
(293 °F)

Power

9,000 W

External length

1,750 mm
(68.9 in)

External height

950 mm
(37.4 in)

External depth

780 mm
(30.71 in)

Description

Product Introduction
Designed to evaluate the resistance of biological indicators under pressure-steam sterilization. Suitable for pharmaceutical and medical device manufacturers, food and drug regulatory authorities, third-party testing laboratories and biosafety facilities.

Features
  • Intelligent operation: one-click automatic water filling, sterilization and exhaust.
  • Data integrity and traceability with real-time monitoring to verify sterilization outcomes.
  • Safety functions: door-open protection, automatic pressure relief, staged temperature control, negative-pressure airtightness test and multi-level user management.
  • High stability and precise control.
  • Customizable program parameters and one-click test report generation.

Specifications (table)
Sterilization Method: Pressure Steam Sterilization
Sterilization Target: Biological Indicator
Sterilization Chamber Volume: 5 L
Dimensions: 175.0 x 78.0 x 95.0 cm
Power Supply: AC 380V/50Hz
Weight: 150 kg
Electric Heating Power: 9 KW
Temperature Range: 110-145°C
Vacuum: 2 kPa
Time to Vacuum: <30 s
Come-up Period: ≤8 s
Sterilization Temperature Deviation: ±0.4°C
Come-down Period: ≤5 s
Time Accuracy: ±1 s
Leakage Rate: ≤0.1 kPa/min
Non-condensable Gas: ≤2.5%
Superheated Steam: ≤5°C
Steam Quality: ≥0.98
Sterilization Curve: Yes
Test Report: Yes
Three-level Management: Yes

Applications
  • Pharmaceutical manufacturers
  • Medical device industry
  • Biosafety laboratories

Technical specifications
  • Sterilization Method: Pressure Steam Sterilization
  • Sterilization Target: Biological Indicator
  • Sterilization Chamber Volume: 5 L
  • Dimensions: 175.0 x 78.0 x 95.0 cm
  • Power Supply: AC 380V/50Hz
  • Weight: 150 kg
  • Electric Heating Power: 9 KW
  • Temperature Range: 110-145°C
  • Vacuum: 2 kPa
  • Time to Vacuum: <30 s
  • Come-up Period: ≤8 s
  • Sterilization Temperature Deviation: ±0.4°C
  • Come-down Period: ≤5 s
  • Time Accuracy: ±1 s
  • Leakage Rate: ≤0.1 kPa/min
  • Non-condensable Gas: ≤2.5%
  • Superheated Steam: ≤5°C
  • Steam Quality: ≥0.98
  • Sterilization Curve: Yes
  • Test Report: Yes
  • Three-level Management: Yes

Exhibitions

Meet this supplier at the following exhibition(s):

Bio Asia-Taiwan
Bio Asia-Taiwan

16-19 Jul 2026 Taipei (Taiwan Region)

  • More information
    ISPE Singapore Conference &amp; Exhibition
    ISPE Singapore Conference &amp; Exhibition

    19-21 Aug 2026 Singapore (Singapore)

  • More information

    Other Tailin products

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.