IntroductionThe laboratory refrigerator is designed for storage of reagents, culture media, proteins and other biomedical samples in research, clinical and industrial laboratories. It provides controlled 2–8°C storage across multiple capacities and models.
Product information- Brand: BIOBASE
- Product origin: CHINA
- Delivery time: Within 7 days
- Supply capacity: Factory direct supply
- Model(s): BPR-5V628, BPR-5V650, BPR-5V968
Technical Parameters (table)Model: BPR-5V628 | BPR-5V650 | BPR-5V968
Capacity: 628 L | 650 L | 968 L
Temp. Range: 2~8℃ | 2~8℃ | 2~8℃
Temp. Accuracy: 0.1℃ | 0.1℃ | 0.1℃
Temp. Uniformity: ≤2℃ | ≤2℃ | ≤2℃
Temp. Stability: ≤3℃ | ≤3℃ | ≤3℃
Recovery Time (recover to 8℃ at ambient 32℃): ≤15 min | ≤15 min | ≤15 min
Cooling Time (cool to 6℃ at ambient 32℃): ≤100 min | ≤75 min | ≤100 min
Control System: Microprocessor control
Display: LED
Alarm: High/low temperature alarm; thermostat fault alarm; door switch alarm; power failure alarm (8 h)
Refrigeration Type: Air-cooling
Refrigerant: R290 / 150 g (all models)
Compressor: International-brand compressor (1)
Condenser & Evaporator: Copper tube with aluminum fins
Defrost: Automatic defrost
Construction / Insulation: Polyurethane (cyclopentane) insulation
Internal / External Material: Sprayed steel plate
Door: Electrically heated double glass doors (×2)
Power Consumption: 300 W
Power Supply: AC220V, 50Hz (standard); 110/220V, 60Hz (optional)
Casters: Yes
Shelves: 10
Standard Accessory: Test hole; USB interface
Optional Accessory: RS485; printer; temperature recorder
Internal Size (W*D*H): 1100*454*1325 mm | 1100*479*1325 mm | 1100*684*1325 mm
External Size (W*D*H): 1220*630*1885 mm | 1220*630*1885 mm | 1220*860*1885 mm
Package Size (W*D*H): 1340*750*2100 mm | 1340*750*2100 mm | 1340*980*2100 mm
Net Weight: 189 kg | 212 kg | (not specified)
Gross Weight: 223 kg | 256 kg | (not specified)
Features / Technical specifications- Microprocessor temperature control with LED display; 0.1℃ accuracy
- Multiple alarms: high/low temperature, thermostat fault, door switch, power failure (8 h)
- Air-cooling system using R290 (150 g) refrigerant and international-brand compressor
- Automatic defrost; sprayed steel plate interior/exterior; polyurethane (cyclopentane) insulation
- Electrically heated double glass doors to prevent condensation
- Standard test hole and USB interface; optional RS485, printer, temperature recorder
- Mobility via casters and up to 10 adjustable shelves
- Available capacities across three models to match storage needs
- Standard power AC220V 50Hz; optional 110/220V 60Hz
NotesCustom voltage and optional accessories available on request; third-model weight values not specified in manufacturer data.