Heating oven M 115
dryingfor temperature testingfor general applications

Heating oven - M 115 - BINDER GmbH - drying / for temperature testing / for general applications
Heating oven - M 115 - BINDER GmbH - drying / for temperature testing / for general applications
Heating oven - M 115 - BINDER GmbH - drying / for temperature testing / for general applications - image - 2
Heating oven - M 115 - BINDER GmbH - drying / for temperature testing / for general applications - image - 3
Heating oven - M 115 - BINDER GmbH - drying / for temperature testing / for general applications - image - 4
Heating oven - M 115 - BINDER GmbH - drying / for temperature testing / for general applications - image - 5
Add to favorites
Compare this product

Characteristics

Function
heating, drying
Applications
laboratory, for temperature testing, for general applications
Type
forced convection, forced air, hot air
Temperature control
ventilated
Configuration
benchtop
Number of doors
1-door
Other characteristics
automated
Temperature range

Max.: 300 °C
(572 °F)

Min.: 23 °C
(73.4 °F)

Capacity

113 l
(29.85 gal)

Description

Product description
With a maximum temperature of 300 °C and extensive programming options, the M series material test chambers are designed for material and aging tests. High air flow and reinforced fans ensure rapid heating and homogeneous temperature distribution throughout the interior.

Benefits
  • Uniform drying and test conditions thanks to APT.line™ preheating chamber
  • Consistent test conditions across the usable volume independent of sample size and quantity
  • Excellent thermal insulation reducing operating costs
  • Extensive programming and data logging options for reproducible test cycles


Important characteristics
  • Temperature range: from +23 °C above ambient temperature up to 300 °C
  • High temperature accuracy using APT.line™ technology with increased heating output
  • Reinforced fan with adjustable speed
  • Electromechanical control of the exhaust air flap
  • Intuitive touchscreen controller with time-segment and real-time programming
  • 2 chrome-plated racks (standard), up to 5 racks possible
  • Independent adjustable temperature safety device Class 2 (DIN 12880) and Class 3.1 option with visual/acoustic alarm selectable at the controller
  • Failsafe backup sensor Pt 100
  • Computer interface: Ethernet
  • Internal data logger; measured values available in open format via USB


Technical specifications
Data
Article Number: 9010-0372
Designation: M115-230V
Option model: Standard

Performance Data Temperature
Article Number: 9010-0372
Temperature range: +23 °C above ambient temperature to 300 °C
Temperature uniformity at 150 °C: 1.0 ± K
Temperature fluctuation at 150 °C: 0.2 ± K
Heating up time to 150 °C: 11 min
Recovery time after door opened for 30 s at 150 °C: 6 min

Air change data
Article Number: 9010-0372
Air change rate at 100 °C: 105 x/h

Electrical data
Article Number: 9010-0372
Rated Voltage: 230 V
Power frequency: 50/60 Hz
Nominal power: 2.4 kW
Unit fuse: 12.5 A
Phase (Nominal voltage): 1~

Dimensions and weights
Article Number: 9010-0372
Interior volume: 113 L
Net weight of the unit (empty): 58 kg
Load per rack: 30 kg
Permitted total load: 150 kg
Wall clearance back: 160 mm
Wall clearance sideways: 100 mm

Housing dimensions (not incl. fittings and connections)
Article Number: 9010-0372
Width net: 710 mm
Height net: 732 mm
Depth net: 636 mm

Internal Dimensions
Article Number: 9010-0372
Interior width: 550 mm
Interior height: 550 mm
Interior depth: 375 mm
Unit doors: 1

Environment-specific data
Article Number: 9010-0372
Sound-pressure level: 46 dB(A)
Energy consumption at 100 °C: 250 Wh/h
Energy consumption at 150 °C: 410 Wh/h

Fixtures
Article Number: 9010-0372
Number of shelves (std./max.): 2/5

Options & Accessories (selection)
  • HEPA air filter (filter classification H14)
  • Interior lighting (27 W)
  • Access port with silicone plug (various sizes/positions)
  • Gas-tight option model; inert gas connection (Ø 10 mm)
  • Inner chamber reinforced (max. total load 170 kg)
  • Door gasket (FKM, silicone-free); door lock (lockable handle)
  • Analog output 4-20 mA (temperature); additional Pt 100 sensors; specimen temperature control
  • Calibration certificates and measurement services; maintenance and commissioning services
  • Software APT-COM™ (BASIC / PROFESSIONAL / GLP)


Downloads
Brochure: Drying and heating chambers (pdf available on site)
Operating manual: Series M Avantgarde.Line (pdf available on site)
Data Sheet: Data Sheet Model M 115 (pdf available on site)

Technical data / specifications
  • Model: M 115
  • Article number: 9010-0372
  • Temperature range: +23 °C above ambient to +300 °C
  • Interior volume: 113 L
  • Interior (W×H×D): 550 × 550 × 375 mm
  • Net weight (empty): 58 kg
  • Rated voltage: 230 V, 50/60 Hz
  • Nominal power: 2.4 kW
  • Noise level: 46 dB(A)
  • Shelves (std./max.): 2 / up to 5 (max load per shelf 30 kg)
  • Air change rate at 100 °C: 105 x/h
  • Energy consumption: 250 Wh/h (100 °C); 410 Wh/h (150 °C)
  • Interfaces: Ethernet; internal data logger with USB export
  • Safety: Class 2 adjustable temperature safety device (DIN 12880) and Class 3.1 option; failsafe Pt 100 backup

Exhibitions

Meet this supplier at the following exhibition(s):

Lab-Supply Dresden
Lab-Supply Dresden

8-08 Sep 2026 Dresden (Germany)

  • More information
    Lab-Supply Hamburg
    Lab-Supply Hamburg

    3-03 Nov 2026 Hamburg (Germany)

  • More information

    Other BINDER GmbH products

    Drying and heating chambers

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.