OverviewThe BK-FPO-V2 freezing point osmometer is designed for clinical and pharmaceutical laboratories to determine osmolarity/molar concentration by measuring solution freezing point depression according to Raoult's principle. It uses a high-sensitivity temperature sensor and automated probe movement to deliver fast results on small sample volumes, suitable for routine QC and research applications.
Product details- Brand: BIOBASE
- Product origin: CHINA
- Delivery time: Within 7 days
- Supply capacity: Factory direct supply
Features- Electronic signature and user classification management; supports CFR PART21 compliant data query and storage of up to 3 years of test records.
- Supports single-point and multi-point linear calibration to ensure measurement accuracy across the range.
- Temperature probe mounted on a screw linear-guide motor for automated, touchscreen-controlled test cycles.
- Dual refrigeration system for short pre-cooling time and rapid throughput suitable for continuous testing.
- Simultaneous display of osmolarity (mOsmol), freezing point value and molar concentration ratio.
- Cooling circuit uses athermal transfer fluid design to reduce maintenance frequency.
- Built-in Chinese Pharmacopoeia database with hundreds of injectable drug entries for quick sample presetting.
Technical ParametersModel: BK-FPO-V2
Measurement range: 0–2000 mOsmol
Sample amount: 100 μl
Testing duration: ≤3 min
Pre-cooling time: ≤3 min
Measurement error: ≤1%
Repeatability: ≤1%
Linearity: ≤1%
Print: Built-in printer
Audit trail: Optional
Environment temperature: 0–30℃ (recommended 15–25℃)
Relative humidity: ≤60%
Power supply: 220V, 50/60Hz (standard); 110V, 60Hz (optional)
External size (W*D*H): 225*275*345 mm
Packed size (W*D*H): 420*545*580 mm
Net weight: 12 kg
Gross weight: 25 kg
Characteristics / technical specifications- Model: BK-FPO-V2
- Principle: Freezing point depression (Raoult)
- Detection element: High-sensitivity temperature sensor
- Measurement range: 0–2000 mOsmol
- Sample volume: 100 μl
- Analysis time: ≤3 min; Pre-cooling: ≤3 min
- Accuracy / Repeatability / Linearity: ≤1%
- Interface: Touchscreen; electronic signature and user management
- Calibration: Single-point or multi-point linear
- Cooling: Dual refrigeration, athermal transfer fluid design
- Data: Built-in printer; optional audit trail; CFR PART21 data storage up to 3 years
- Operating conditions: 0–30℃ (recommended 15–25℃), RH ≤60%
- Power options: 220V 50/60Hz (standard) or 110V 60Hz (optional)
- Dimensions (W×D×H): 225×275×345 mm; Packed: 420×545×580 mm