Product DescriptionThe ITGen Canine Adenovirus II Antigen Rapid Test is an immunochromatographic cassette designed for rapid point-of-care and in-clinic screening of canine adenovirus II (CAV-II) antigen in ocular, nasal or oral secretions. Intended for veterinary diagnostics, it supports quick decision-making for early isolation and treatment pathways when respiratory signs are present.
Production Features- Targeted detection for CAV-II antigen
- High-sensitivity lateral flow strip
- Rapid result time for point-of-care use
- Consistent batch performance
Product ParametersProduction Name: ITGen Canine Adenovirus II Antigen Rapid Test
Target Analyte: Canine Adenovirus II Antigen
Specimen Type: Canine secretions (eye, nose or mouth)
Storage Temperature: 4-30°C
Result Time: 5-10 Minutes (read at 5–10 min; invalid after 15 min)
Packaging: Individually sealed tests
Packaging Specification: 1T
Shelf Life: See expiration date on package
Product SpecificationsSensitivity: 97.22%
Specificity: 96.67%
Accuracy: 97.00%
Format: Cassette lateral flow immunoassay
Detection Method: Chromatographic Immunoassay / Lateral Flow Immunoassay
Reading Time: 5-10 Minutes
Usage: Veterinary diagnostics, point-of-care screening
ContentsTest device: 1
Swab: 1
Buffer tube: 1
Package insert: 1
How to use?- Verify kit contents and ensure test and specimen are at room temperature (15–30°C).
- Unseal the buffer tube and place it upright in the workstation.
- Use the swab to collect secretions from the canine's eye, nose, or mouth; rotate the swab more than 10 times to obtain sufficient sample.
- Close the buffer tube cap, remove the test device from the foil pouch, and place it on a clean, flat surface.
- Add three drops (≈90 μL) of the extracted specimen vertically into the specimen well (S) of the test device.
- Read the result within 5–10 minutes. Results read after 15 minutes are invalid.
Interpretation of ResultsPositive (+): Both control line (C) and test line (T) appear, irrespective of T line intensity.
Negative (−): Only control line (C) appears clearly.
Invalid: No visible control line (C), regardless of test line appearance — repeat test with a new device.
Certifications & Quality- ISO 9001 (Quality Management System)
- GMP (Good Manufacturing Practice)
- CE (European Conformity)
- ISO 13485 (Medical Devices Management System)
- Batch consistency testing and full traceability
- Quality control at each production stage
Technical Specifications- Production Name: ITGen Canine Adenovirus II Antigen Rapid Test
- Target Analyte: Canine Adenovirus II Antigen
- Specimen Type: Eye, nose or mouth secretions
- Storage: 4–30°C
- Result/Reading Time: 5–10 minutes (invalid after 15 minutes)
- Format: Cassette lateral flow immunoassay
- Detection Method: Chromatographic Immunoassay / Lateral Flow
- Sensitivity: 97.22%
- Specificity: 96.67%
- Accuracy: 97.00%
- Packaging: Individually sealed; 1T per pack
- Contents per kit: 1 test device, 1 swab, 1 buffer tube, 1 package insert
- Intended Use: Rapid screening in veterinary practice or point-of-care settings